Department of Clinical Laboratory, Kyoto University Hospital

[1042 / 5G300]
Japanese
 
Ver.19
5.Immunological Test >> 5G.Autoimmunity Related Test>>5G300 thyroid-stimulating antibody

thyroid-stimulating antibody

0

Standard Code (JLAC10)

1 Analyte5G300thyroid-stimulating antibody
Identification0000
Specimen023serum
Method905bioassay
Result Identifying 0100

Specimen

Top Colour Collected Sample Quantity Measured Material Required
HotPink Top blood 6 mL serum 0.3 mL

Specimen Rejection Criteria

haemolysisreject
clotted 
lipaemia 
inappropriate sample volume 
wrong containerreject
urine samples without the appropriate preservative 
received ambient 
unprotected from light 
opening tubes 
incterus 

Specimen Stability Information

Specimen Type Container Temperature Stability
serum Refrigerated

Turnaround Time (TAT)

3 - 4 days

Laboratory

outsourcing (BML, Inc.)weekday (8:30 a.m. - 5:00 p.m.)
night time or weekend

Reference Value

Period / Age
Specimenblood
Methodbioassay
  MaleFemaleUnit
00thyroid-stimulating antibody< 110< 110%
Specimenblood
Methodenzyme immunoassay (EIA)
  MaleFemaleUnit
00thyroid-stimulating antibody≤ 120≤ 120%
Specimenblood
Method 
  MaleFemaleUnit
00thyroid-stimulating antibody< 180< 180%
Specimen
Method
  MaleFemaleUnit
Specimen
Method
  MaleFemaleUnit
Specimen
Method
  MaleFemaleUnit
Specimen
Method
  MaleFemaleUnit
Specimen
Method
  MaleFemaleUnit

Critical Value

High Value Low Value